Analysis of measurement deviation with single sheet testing method for electrical steel

Qian XIANG,kaimin WU,Shuang HUANG,Junpeng ZHANG
2017-01-01
Abstract:The differences of SST (82) and SST (92) single sheet testing methods were analyzed,and the measurement deviation between each other was also quantitativly estimated.The results showed that the core loss tested by SST (92) single sheet testing method was about 5.03 % higher on average than by SST (82).It was mainly because the effective magnetic path length of the SST (82) single sheet testing method varied and had large discreteness,which was related to the magnetic yoke.In addition,the H coil method to measure directly the sample magnetic field intensity eliminated the influence of the effective magnetic path length,so it could be regarded as a reliable alternative method.
What problem does this paper attempt to address?