Feasibility of Penetrant Testing on Surface Axial-Radial Cracks of GH4169 Super Alloy Turbine Disk

Haiyan QIAO,Xuedong REN,Yiwei SHI,Chunhu TAO
DOI: https://doi.org/10.11868/j.issn.1005-5053.2016.6.015
2016-01-01
Abstract:The post emulsifiable and water-washable fluorescent penetrant testing were carried out with ZL-27A and ZL67 respectively. Ultrasonic cleaning by detergent were used for 30 minutes before penetrant. The parts were immersed and drained for 60 minutes. The macroscopic and microscopic characteristics of cracks were researched using the split mirror and scanning electron microscope. The re-sults show that the outgrowth of high temperature oxidation plugs up the forging cracks. Thus the penetrant testing is not effective in de-tecting this type of cracks.
What problem does this paper attempt to address?