Optimization design of structure of bottom spray quenching tank

Xin Li,Hai Zhang,Guo Zheng,Xiaodong Zhang
DOI: https://doi.org/10.13251/j.issn.0254-6051.2016.06.045
2016-01-01
Abstract:To improve the cooling uniformity of bottom spray quenching ( BSQ) , the structure of quenching tank was optimized by changing the inflow direction of water and variable diameter quenching tank .the influence of quenching cooling at different quenching tank structure was studied .The results show that the flow rate on either side of the steel tube is improved significantly when the inlet direction changes into tangential under the same boundary conditions , and the cooling capacity of quenching tank are improved effectively .Through the use of the variable cross-section quenching tank , the cooling uniformity of axial or the cooling uniformity of both inside and outside of the tube surface is more superior than the uniform diameter quenching tank .
What problem does this paper attempt to address?