Application of Metal Intensifying Screen to the Double-film Technology with Equal Exposure Sensitivity

Hai-quan MA,Bei LI,You-du HE,Gang MI,Hong-xun WANG,Yi-wei SHI
DOI: https://doi.org/10.11973/wsjc201601005
2016-01-01
Abstract:In the present work, with the film sensitivity and film density as evaluation parameters, the combination patterns of double-film technology with metal intensifying screen were studied with titanium alloy step blocks.The results show that in accordance with the regulation of HB/Z60《Radiographic Inspection》,for the parts of thickness being less than 42mm :if the maximum and minimum thickness ration of detected part is less than 5.5, the combination pattern of MX125 MX125 can be used,if the ration is less than 3.0,the combination pattern of MX125,MX125 and AA400 AA400 can be used.
What problem does this paper attempt to address?