Analysis on Steady-state Operating Range and Off-limits Malfunction Mechanism of Electrical Spring

CHENG Yisheng,LU Zhengang,WANG Keyou,ZHAO Guoliang,HUANG Xin,LIU Jinsong
DOI: https://doi.org/10.7500/AEPS20161207003
2017-01-01
Abstract:With the background and basic principle of the electrical spring (ES) described,the modulability of ES is analyzed at length by the vector diagram method,and the operation range of the line voltage under which ES can work is investigated.Besides,the malfunction mechanism is analyzed,and a new computational method for optimizing the specified value of critical load voltage is found.When the line voltage changes in the range,the critical load voltage can be stabilized on the standard value by ES,but when changes are beyond the range,the ES will break down,and the critical load voltage will deviate from the standard state,or even the system can become unstable.Given the permissible fluctuation range of the critical load voltage,the expanded safety regulation domain of the ES system can be obtained by optimizing the specified value of the critical load voltage.Finally,the analysis results are validated by simulation and experiment results.
What problem does this paper attempt to address?