Energy Consumption Characteristics Analysis on a Coal-Fired Power Plant Operating in Deep Peaking Mode

Guozhu ZHANG,Juntai ZHANG,Yawei LI,Ming LIU
DOI: https://doi.org/10.3969/j.issn.1000-7229.2017.10.008
2017-01-01
Abstract:With the increasing of installed power capacity from renewable energy,more and more thermal power plants are subject or serve the deep load cycling.Therefore,it is needed to study the energy consumption characteristics of power plants under ultra-low load.Taking a 350 MW unit as example,this paper establishes the calculation models of off-design conditions and exergy analysis model for units,and predicts the energy consumption characteristics of power plants under ultra-low load.The results show that the standard coal consumption rate for power generation increases with the decreasing of power load.The standard coal consumption rate for power generation are increased by 15.90,25.81,42.32 and 70.43 g · (kW · h)-1 when the load ratios are 50%,40%,30% and 20% compared with that when the load ratio is 100%,respectively.The results of exergy analysis show that the exergy efficiencies of boiler subsystem and turbine subsystem all decrease significantly when the power plant operates under low load ratio.
What problem does this paper attempt to address?