An Improvement on the Circulation Oxidation Tank of an Absorption Tower for Wet Flue-gas Desulfurization

杜谦,吴少华,刘辉,秦裕琨
DOI: https://doi.org/10.3969/j.issn.1001-2060.2005.01.022
2005-01-01
Abstract:After the three towers of a wet flue-gas desulfurization system was grouped into one, there emerged the problem of a decrease in desulfurization efficiency and gypsum quality. To cope with this problem, an improved scheme was put forward, which consists in dividing the circulation oxidation tank at the bottom of the absorption tower into an oxidation tank and a material-feed tank. Moreover, tests were conducted on a parallel-flow falling-film wet desulfurization plant before and after the implementation of the improved scheme. The results of the tests indicate that the improved desulfurization plant has alleviated the contradiction between the desulfurizaton efficiency and the gypsum quality. The high pH value of the material-feed tank makes it possible to maintain a high desulfurization efficiency in the tower, while the low pH value of the oxidation tank is favorable to the dissolution of limestone and the oxidation of SIV, thereby enhancing the quality of gypsum.
What problem does this paper attempt to address?