Cooling performance contrast analysis of turbine vane by air and steam coolant

Chao MA,Mi HUANG,Shu-sheng ZANG
DOI: https://doi.org/10.13738/j.issn.1671-8097.2014.02.009
2014-01-01
Journal of Thermal Science and Technology
Abstract:The first stage guide vane of a real turbine cooled by air and steam were respectively simulated in the heat-flow coupling method .The results demonstrate that in the same temperature ratio and the same mass flow of the coolant condition ,w hen using steam-cooling method ,the cooling efficiency is improved about 0 .1 than air-cooling ,but the main flow is also interacted more greatly ;w hen getting the same cooling efficiency ,the steam consumption is only about 60% of the air ,the main flow is got less interaction by using steam cooling .The numerical model was validated by the experiment in air cooling ,and the results are in good agreement with each other .
What problem does this paper attempt to address?