Influence of Transition Section to Clocking Effects of Hot Spot and Cooled Turbine

Ying YE,Zhao YIN,Honglei ZHAO,Qin GAO,Chunqing TAN
DOI: https://doi.org/10.16120/j.cnki.issn1009-2889.2017.01.004
2017-01-01
Abstract:Heat transfer conjugate (HTC) calculation methodology was used to simulate the cooled stators and transition section of a micro-small gas turbine,in order to study the influence of transition section on clocking effects of hot spot and cooled stators.The results show that: hot spot moves to the hub in the C-type transition section;compared with the axial flow transition section, the C-type transition section reduces the clocking effects, which is due to the translation of hot spot and the three dimensional characteristics of the flow.
What problem does this paper attempt to address?