Semi-tomographic gamma scanning technique for activity detection of radioactive waste drum

Kaiyuan RAO,Weiguo GU,Xinhai TANG,Dezhong WANG,Yuanwei MA
DOI: https://doi.org/10.11889/j.0253-3219.2018.hjs.41.050501
2018-01-01
Nuclear Techniques
Abstract:[Background] Segmented gamma scanning (SGS) and tomographic gamma scanning (TGS) are the normal standard non-destructive assay (NDA) techniques for low intermediate waste drum detection. [Purpose] This study aims to evaluate the performance of semi-tomographic gamma scanning (STGS) for waste drum of nuclear power plant (NPP). [Methods] The principles of SGS and TGS are synthesized in the STGS method and the implementation of its algorithm, each segment of the waste drum is divided into annual voxels and tomography is used in the radiation reconstruction. The accuracy of STGS is verified by MCNP calculation for the 400 L standard waste drums which contains three types of nuclides. The cases of point source and uniform materials are employed for comparison. [Results] The experimental results show that the reconstruction error and statistical bias for STGS can be controlled lower than 50% and is always half or less of SGS while maximum error of SGS is over 100%. The detection time of STGS is obviously shorter than TGS. [Conclusion] STGS can keep the balance between accuracy and detection time, it is an effective method for non-destructive assay of 400 L radioactive waste drums with high density.