A density correction method for radioactive waste drum based on SRGS technology

Shiwei Liao,Wenbao Jia,Zhongqi Wang,Can Cheng,Wei Cheng,Dong Zhao,Hao Fei,Qing Shan,Daqian Hei,Yongsheng Ling
DOI: https://doi.org/10.1016/j.apradiso.2024.111337
IF: 1.787
2024-05-02
Applied Radiation and Isotopes
Abstract:The segmented ringed gamma scanning (SRGS) technique represents an advancement in segmented gamma scanning (SGS) technology used for detecting the density of radioactive waste drums, offering enhanced measurement accuracy. However, significant occur errors in the reconstruction of matrix densities due to the non-uniform distribution of density in radioactive waste and the conical beam emitted from the transmission source collimator. This paper proposes a density correction method based on dichotomy to address this issue. The efficacy of this method was verified through both simulations and experiments on a sample containing five different materials, utilizing 137 Cs and 60 Co for transmission and emission measurements, respectively. The experimental results demonstrate that the errors in the corrected matrix densities are reduced, falling within a margin of 16.8%. Additionally, the corrected reconstruction error of the activity is approximately 25% of the uncorrected results.
nuclear science & technology,radiology, nuclear medicine & medical imaging,chemistry, inorganic & nuclear
What problem does this paper attempt to address?