Optimalizing electron beam parameters of linear accelerator based on Monte Carlo simulation

Fan ZHANG,Ainong XIAO,Haibiao WU,Xiaohong AI,Guopu QU,Pian LI,Wenjun LI,Manbo CAI
DOI: https://doi.org/10.11889/j.0253-3219.2018.hjs.41.060201
2018-01-01
Nuclear Techniques
Abstract:[Background] With the development of radiation technology, it needs to improve the accuracy of dose simulation. [Purpose] Build up a simplified benchmarking procedure to determine the incident electron beam parameters independently using a Monte Carlo linear accelerator model. [Methods] A 10 cm×10 cm field is simulated to acquire the parameters influence on the dose distributions for Varian IX 6 MV megavoltage electron beams. [Results] The calculated depth doses had no significant changes when the electron mean energy and radial intensity varied in 5.5~6.4 MeV and 0.1~0.4 cm respectively. And the dose profile simulated with an electron radial intensity in 0~0.19 cm had a good agreement with the measured dose profile in the main field while obvious discrepancies in the penumbra region. The mean angular spread was found to be 0.3° to get good matching between calculations and measurements at all considered depths. [Conclusion] Accurate dose distributions are achieved by using the incident electron beam parameters benchmarked with the proposed procedure. As the percentage depth doses and dose profiles are insensitive to the electron energy and radial intensity correspondingly, they are feasible to benchmark individually.
What problem does this paper attempt to address?