Temperature field analysis for the main shielding of the 2-MW thorium-based molten salt experimental reactor

Jie HE,Xiaobin XIA,Jun CAI,Deng PAN,Yu PENG,Jianping HUANG,Guoqing ZHANG
DOI: https://doi.org/10.11889/j.0253-3219.2016.hjs.39.040601
2016-01-01
Nuclear Techniques
Abstract:Background:Molten salt reactor is a fourth generation advanced reactor. The concrete wall is the key part of this high-temperature reactor shielding, so temperature field analysis is important. Purpose: This study attempts to calculate the temperature field of the TMSR-LF1 (2-MW liquid-fueled molten salt experimental reactor) shielding, and judge if it meets the design requirements. Methods: In accordance with the problem that MCNP (Monte Carlo N Particle Transport Code) results cannot be directly imported into Fluent, a program which converts MCNP results to the spatial distribution of power density, and imports the spatial distribution of power density into the Fluent in the form of User-Defined Function (UDF) was developed by using Python programming language to realize the coupling of the two. According to TMSR-LF1 design parameters, a one-eight physical and thermal model of the whole reactor is established, using code MCNP and Fluent. Reactor radiation shielding thermal analysis adopts the assumptions that the different environment temperatures are 5°C, 18°C, 25°C, 30°C, 35°C and 40°C, respectively.Results: The maximal values of temperature and temperature gradient in the radiation shielding concrete wall are 67.42 °C and 78.40 °C·m?1, which are lower than limit values.Conclusion: The radiation shielding concrete wall can meet the design requirements.
What problem does this paper attempt to address?