Effect Analysis of Temperature Gradient on Metal Bellow Mechanical Performance

Chuang WANG,Wei-guo GU,De-zhong WANG,Yu LI
DOI: https://doi.org/10.3969/j.issn.0258-0918.2017.04.022
IF: 1.2
2017-01-01
Nuclear Science and Engineering
Abstract:The bellow in molten salty control valve is essential to ensure the valve safe operation. Surrounding by molten salt, the control valve bellow loads external pressure,axial displacement and high temperature with large temperature gradient, which is error-prone part. In this paper,U-shape and V-shape bellows mechanical performances have been compared by means of ideally plastic material model and structural-thermal coupling element in ANSYS. Results show that axial displacement load is the main reason for bellows failure,and stress magnitude remains the same in both structures,while,stress in V-shape bellow is much smaller than U-shape bellow under the same pressure and temperature,so V-shape bellow has been chosen for molten salty control valve. In addition,a study on stress distribution,plastic strain and limit displacement load have been carried out under multiple temperature gradients, which is design temperature load,temperature load when the valve is covered with heat preservation and room temperature. As can be seen from the results,limit displacement load under high temperature is only equivalent to one-third compared with limit load under room temperature, and heat preservation has little effect on bellows limit displacement load even though temperature on bellow has increased.
What problem does this paper attempt to address?