Study on the Ultrasonic Velocity of Generator Stator Insulation

SUN Xiang,HAO Yanpeng,GAO Naikui
DOI: https://doi.org/10.3969/j.issn.1003-6520.2005.02.007
2005-01-01
Abstract:In this paper, the ultrasonic pulse-echo method is used to measure statistically the ultrasonic velocity of stators insulation, which have been in service for 0, 16, 18 and 23 years respectively. Particularly, a specific program is prepared to calculate the ultrasonic velocity. The decrease of minimum velocity with increase of service time of generator is faster than that of average velocity. The minimum velocity and the average velocity can reflect the aging state of stator insulation effectively.
What problem does this paper attempt to address?