Study On Multi-Factor Aging Characteristics Of Generator Stator Bars

Jiang Yuao,Du Yu,Gao Naikui,Lui Libing
DOI: https://doi.org/10.1109/ICPADM.2006.284171
2006-01-01
Abstract:A long-term accelerated aging test is conducted on the stator bar of 300MW/18KV generator by using a multi-factor aging test system which combines electrical, thermal and vibrational stresses. Under the multi-factor aging, the developing rule of the dielectric loss, partial discharge parameters and breakdown voltage of stator bar sample with aging time is investigated. Moreover the characteristic parameters used to assess the aging condition of stator insulation are stated, which provides a basis to predict the breakdown voltage of stator bar in generator.
What problem does this paper attempt to address?