Design of Multi-channel Digital Neutron Flux Density Measurement System with Wide Range Coverage for ITER

Jun WU,Chen YUAN,Ze-jie YIN
DOI: https://doi.org/10.7538/yzk.2017.51.06.1071
2017-01-01
Abstract:Aiming at the wide range,high integration and real-time performance on the neutron flux density measurement by International Thermonuclear Experimental Reactor (ITER) requirements,a set of multi-channel neutron flux density measurement system based on PCI extension for instrumentation (PXI) bus was designed.This system comprised a specially designed current-sensitive preamplifier and main electronics plug-in mainly including high speed analog-to-digital converter (ADC) and field programmable gate array (FPGA).The fully digital signal processing technique was utilized to join pulse counting mode and Campbelling mode,significantly increasing the neutron flux density measuring range and system integration.The neutron flux density estimation algorithm based on pulse piling-up proportion was able to choose and switch measuring modes accurately and automatically.The experiment result shows that this system achieves real-time neutron flux density measurement on a single fission chamber,and enhances upper limit of neutron radiation dose larger than 1.7 × 1010 cm-2 · s-1.The entire scale relative error is below 7.1%.
What problem does this paper attempt to address?