Experimental Study of Upper Plenum Entrainment in AP 1000

Yan XIANG,Du-cheng SUN,Ying-wei WU,Peng ZHANG,Sui-zheng QIU,Guang-hui SU
DOI: https://doi.org/10.7538/yzk.2016.50.01.0061
2016-01-01
Abstract:The test loop in the scaled ratio 1∶5.6 was constructed to repeat the process of upper plenum entrainment in AP1000 .The upper plenum entrainment rate in differ‐ent steam flow rates and different liquid levels of the pressure vessel was studied .The results indicate that the entrainment rate increases with the liquid level in the vessel and is affected by the steam flow rate weakly .The entrainment rate remains stable at lower liquid level .The upper plenum entrainment strengthens significantly with the insertion of the reactor internals .