Measurement and Evaluation of the Photobiological Safety of Ultraviolet Cooker Hood

Min Cheng,Lei Liu,Qingming Xia,Zhiyong Jiang,Anqi Yu
DOI: https://doi.org/10.3969/j.issn.1004-440X.2014.04.008
2014-01-01
Abstract:In this paper, the ultraviolet ( UV) cooker hood which appeared in the market recently , was tested and analyzed on its photobiological safety , according to the photobiological safety requirements of the newest standard IEC 62471: 2006.By testing of actinic UV hazard for the skin and eyes and near-UV hazard for the eyes from UV radiation , it illustrated that the hazard of actinic UV hazard for the skin and eyes was much bigger than near-UV hazard for the eyes , which is caused by the UV light source whose main wavelength is 254 nanometer.What's more, the relationship was proposed in this paper that UV hazard limits of UV light source about illumination and exposure time .Meanwhile , in order to reduce the hazard of UV cooker hood , effective solution was also proposed in the paper .
What problem does this paper attempt to address?