Study on measuring conducting liquid flow with gas by electromagnetic vortex flowmeter

Chunchang Wang,Kejun Xu,Wei Xu,Jianping Wu,Liping Liang,Wei Xiong,Xiaoxue Yan
DOI: https://doi.org/10.13382/j.jemi.2018.01.023
2018-01-01
Abstract:There are large measurement errors in electromagnetic vortex flowmeter when measuring conductive liquid flow mixed with gas,since the existed signal processing method obtains the wrong flow signal frequency.For this reason,an algorithm based on signal differential and fast Fourier transform (FFT) spectrum analysis is proposed to calculate the correct frequency of the flow signals.It can amplify high frequency signal and suppress interference of low frequency bubble noise,in order to make the energy of flow signals in whole is dominant.An electromagnetic vortex flow transmitter based on DSP is developed,and an experimental process is designed to perform gas-liquid two-phase flow experiments.The testing results show that when gas volume fraction is less than 3.9%,the measurement errors of the transmitter are smaller than ± 3%,which greatly reduces the conductive liquid flow measurement error.
What problem does this paper attempt to address?