Research on the Detection of Local Defects of Pipes Based on Dual Receivers

Yi-bing SHI,Qing-wang LUO,Zhi-gang WANG,Wei ZHANG,Dong MA
DOI: https://doi.org/10.3969/j.issn.0372-2112.2018.01.027
2018-01-01
Abstract:In the internal inspection of pipes based on Remote Field Eddy Current (RFEC),when transmitter passed by defects on pipe,signals tested by receivers is superimposed by the secondary peaks.Secondary peaks are caused by defects locate near transmitter,and lead to wrong assessment of qualification of defects.This paper applied dual receivers for removing secondary peaks.In proposed method,two receivers are set coaxially to transmitter in remote field to get two differential signals.With these two differential signals,Wiener deconvolution filter is employed to obtain secondary peaks and filter testing noise.Further,an array of sensors is set in remote field to test local defects.The secondary peaks can be subtracted from signals tested by sensors by using the dual-receiver.The feasibility of proposed method is validated by testing tool and experimental pipe.
What problem does this paper attempt to address?