Design and fabrication of long period fiber gratings in microfiber and the temperature sensing system

Ru-gang WANG,Feng ZHOU,Wei-bin KONG,Xiao-fang YANG,Li ZHAO,Xu-ping ZHANG
DOI: https://doi.org/10.16136/j.joel.2017.04.0333
2017-01-01
Abstract:In order to obtain high-precision temperature sensing system,a fiber grating temperature sensing system based on a long period grating (LPG) is proposed and experimentally demonstrated.Firstly,a microfiber with a diameter of 6.2μm is obtained by drawing the conventional single mode fibers.Secondly,a long period grating (LPG) is obtained in the microfiber by using CO2 laser,and the grating period is about 100 μm.A temperature sensing system with the Mach-Zehnder interferometer (MZI) and LPG is designed,a acousto-optic modulator (AOM) is used to shift the frequency in the system,and a 200 MHz microwave signal is obtained.With the increase of measurement temperature,relative intensity of the microwave signal is gradually increased,and the slope is about 0.46 (a.u)/℃.In 30 min,the stability of the microwave signal is measured,and the fluctuation in the intensity is about 0.5 dB,and the experimental results show that the system has high stability.
What problem does this paper attempt to address?