Calibration method of electronic compass with error-separation based on non-magnetic turntable

Ke GAO,Xin-hua LIN,Zhi-wei CHU,Jing-bo WU
DOI: https://doi.org/10.13873/J.1000-9787(2017)02-0021-04
2017-01-01
Abstract:Full digital electronic compass is developed by using magnetic-inductive sensors and acceleration sensors and the error-separation method based on non-magnetic three-axis rotation platform is presented to calibrate the magnetic compass.The parameters about misalignment and non-orthogonality of the sensor axes and the response curve of sensor output to earth magnetic intensity are obtained.Furtherly,the sensitivity of magnetometers and the bias from the offset and hard-iron interference are estimated according to the response curve.The independent effect of non-orthogonality and misalignment,bias and inconsistence in sensitivity on the heading error can be evaluated with the error-separation method,respectively.After calibration,the maximum heading error of magnetic compass is about 0.4° when both pitch angle and roll angle are in the range of 60°,indicating the error-separation method is effective and efficient to calibrate electronic compasses.
What problem does this paper attempt to address?