Twelve-position calibrating method without north reference for magnetic compass

GUO Peng-fei,REN Zhang,QIU Hai-tao,DING Xin-chun
2007-01-01
Abstract:Among the many factors affecting the system errors of compass(i.e.bias,scale factor error and install alignment error,etc.),one large contributor comes from the difference characteristics of magneto-resistive sensors during production and installation.A 12-position calibrating method without north reference for magnetic compass was developed.The equations of three-axis bias,scale factor error and install alignment error was deduced in the proposed method which is totally based on the magnetic field of up direction.The effect of hard iron distortion is equaled to the variation of three-axis bias.The effect of soft iron distortion is equaled to the variations of three-axis scale factor and install alignment.Three-axis bias,scale factor error and install alignment error with hard iron and soft iron effects were calibrated by the proposed 12-position calibrating method without using north reference for magnetic compass.And the experiment results demonstrate that the heading accuracy after compensation is 0.2° on horizontal plane,the heading accuracy after compensation is 0.4° for tilt angle of 26°.