Preparation and research on silicon-based high throughput array chip of single cell

Xiang MENG,Xiao-feng ZHOU,Lu-feng CHE
DOI: https://doi.org/10.13873/J.1000-9787(2017)03-0014-03
2017-01-01
Abstract:Array chip with key structure of SiO2 is prepared based on MEMS technology. Cells can adhere to SiO2 directly. Cell adhesion efficiency reach the highest value of 85% at 3μm in the range of 0. 7~23μm,because appropriate aspect ratio can enhance the twine between cellular pseudopod and nanowires. Single cell array saturation is analyzed on different incubation time and cell concentration respectively. And the saturation reach highest value of 83% when incubation time is at least 4h and cell concentration is 1. 5,because the sufficient interaction between cellular pseudopod and nanowires. Experimental result shows the produced array chip of single cell has higher cell adhesion efficiency and array saturation which meet the standard of high throughput.
What problem does this paper attempt to address?