Operating Condition Study on Online Measurement of Wet Aerosol Particle Concentration

Bing LI,Wen-yun WEI,Ling-ling LIU,Xing-can YANG,Hui YU,Jia-hua ZHU,Hoeflinger Wilhelm
DOI: https://doi.org/10.3969/j.issn.1003-9015.2016.00.038
2016-01-01
Abstract:Moisture absorption, fogging and entrainment can affect the measurement of aerosol particle size and concentration in wet dedusting systems when using light scattering methods. A dilutor can be applied to increase measurement accuracy by reducing relative humidity and promoting droplet evaporation. The effects of droplet diameter, gas temperature, relative humidity and droplet concentration on droplet evaporation time were discussed based on the dynamic equation for droplet evaporation. The results show that when the relative humidity of outlet gas is lower than 15.7%, and the droplet temperature and gas temperature are 20℃ and 20~40℃ respectively with droplet concentration lower than 2×104 P×cm-3, the droplets with diameter of 0.2~5μm can be completely evaporated in the dilutor. Critical evaporation operating conditions at different gas temperatures, humidity and droplet concentrations were obtained when the droplet diameter is 5μm, and the gas temperature and relative humidity are 20℃ and 18%respectively with critical evaporation droplet concentration of 104 P×cm-3. The results of particle size distribution obtained with the dilutor under critical operation conditions show good agreement with that of experimental design.
What problem does this paper attempt to address?