Gas Flow and Distribution in Circle Distributor

Zhimin Lu,Chunzhong Li,Dezi Cong,Shuming Zhang,Xiong SHEN
DOI: https://doi.org/10.3969/j.issn.1005-9954.2001.02.006
2001-01-01
Chemical engineering
Abstract:The fluid field in a gas distributor with a rectifying ring was measured with LDV.In the outer passage,there was a great deal of circulation gas and the flow was in variablemass way.In the inner passage,the circulation gas was eliminated,but the velocity impulsed strongly.Gas flowed in radial direction uniformly nearby the pores on the wall of center pipe.The influence of the opening ratio and the opening mode of the rectifying ring on the gas distribution effect was also measured with a calandria manometer.The flow through the pores of the center pipe could be uniformly distributed by adjusting the opening ratio of the rectifying ring.In the range of this experiment,the energy loss of the distributor could be decreased with the rectifying ring.
What problem does this paper attempt to address?