Thermal Analysis of Different Starting Processes and Preload Analysis of Bolted Joints of the Cylinder Head in BOG Compressor

Xin DU,Yi YAN,Yun LI
DOI: https://doi.org/10.3969/j.issn.0254-6094.2017.06.009
2017-01-01
Abstract:Making use of finite element analysis to analyze and compare the BOG compressor' s three starting processes were implemented from the change of cylinder temperature field and the bolt preload distribution. The result shows that, as for the pre-cooling starting process at -160℃, the cylinder' s maximal temperature difference and the bolt's maximal preload unevenness stay at 52℃and 20.4%, respectively, and this starting process is the most stable; regarding to -40℃ pre-admission process, the cylinder ' s maximal temperature difference and the bolt' s maximal preload unevenness stay at 67℃ and 25.4%, and this starting process is the most unstable.The direct starting process stays between them.