EXPERIMENT ON STRUCTURAL BEHAVIOR OF T-TYPE PERFOBOND RIB GFRP SHEAR CONNECTORS

Hailin Huang,Hui Zhu,Mingqiao Zhu,Chuijun Zeng,Weirong L,Zhijin Zhou
DOI: https://doi.org/10.13204/j.gyjz201603004
2016-01-01
Abstract:A new T-type perfobond rib GFRP shear connector was put forward to improve the interfacial bond properties between GFRP and concrete.Push-out tests were conducted to investigate the mechanical behaviors of three T-type perfobond rib GFRP shear connectors. The failure patterns, crack development rules and load-slip relationships, were obtained by contrast experiments. Results showed that T-type perfobond rib GFRP shear connectors could provide good shear deformation capabilities after interface slipping, all the failures started with concrete shear failures which showed the same failure mechanism as PBL shear connectors, ultimate bearing capacity depended on the shear strength of concrete block and concrete tenons through the T-type rib holes.The formula of ultimate bearing capacity was proposed, the calculated results showed that this method had enough safety coefficient, which provided a reference for the engineering design.