Thermodynamics and Thermal Stress Analysis of Plate-fin Structures in LNG Heat Exchanger

Hong-qiang MA,Wei-hua CAI,Jie CHEN,Yang YAO,Yi-qiang JIANG
DOI: https://doi.org/10.3969/j.issn.1003-0344.2015.03.010
2015-01-01
Abstract:In orderto ensure the safe and reliable operation of Plate-fin structure in plate-fin heatexchanger which was used to Liquefied Natural Gas(LNG)in a large-scale cold-box.AFinite ElementModel(FEM)based on thermalelastic theory was established to simulate influence of operation parameters for the maximum equivalent thermal stress in plate-fin structure. The result shows that the maximum equivalent thermal stress grows steadily with the temperature difference between Natural Gas (NG) and Mixture R efrigerant (MR) and with pull load, decreases with NG or MR temperature and with press load. Addition, the maximum equivalent thermal stress increase with NG or MR pressure, and the influence of NGpressure is greater obviously.These results would provide some constructive instructions in the design and safe operation for plate-fin heatexchanger in large-scale LNG cold box.