Optimal Designs of Square Concrete Filled Thin-walled Steel Tube Long Columns with Straight Ribs

Yong CHEN,Yao-chun ZHANG,Yao WANG
DOI: https://doi.org/10.3969/j.issn.1001-6864.2005.04.019
2005-01-01
Abstract:According to the experimental results of nine tests of square concrete filled thin-walled steel tube(CFTST) long columns with or without straight ribs,the influence of the loading eccentricity and the width of straight ribs are analyzed by the method of optimal design.The study shows that the mechanical capability of CFTST long columns with straight ribs can be improved effectively.Compared with those with straight ribs,the limit capability of those with(70?mm) eccentricity increases by 18.7%,that of those with 40mm-eccentricity by 18.4%,that of those with axial pressure by 21.1%,which proves that CFTST long columns with straight ribs can largely improve the loading capacity and are therefore superior in structure and turn out to be an optimal design.
What problem does this paper attempt to address?