Ozone control and concentration prediction model in high voltage electrostatic coupling catalysis for indoor air purification

Bangjun LI,Zeyun FAN,Yi ZHANG,Jianwei SHI,Wenfeng SHANGGUAN
DOI: https://doi.org/10.12030/j.cjee.201605154
2017-01-01
Abstract:Electrostatic precipitators have attracted tremendous attention for air purification due to their high PM 2.5 removal efficiency and low pressure drop.However,drawbacks such as the generation of hazardous ozone in high voltage modules in air purification facilities cannot be ignored.Therefore,in this study,methods for ozone concentration control and prediction were studied.In the experiment,the ozone concentration was analyzed before and after coupling of a high-voltage electrostatic module and catalyst module in airtight cabins with different dimensions.A practical prediction model of ozone concentration for indoor environments with electrostatic air cleaners was established and further experiments were carried out for validation.The mass balance equations and attenuation characteristics of ozone applied in the model establishment were based on an assumption of a wellmixed air volume.Results showed that the coupled high-voltage electrostatic module and catalyst module could effectively control the ozone concentration,keeping it below the safety limits for eight hours.It was concluded that indoor ozone concentration could be effectively predicted using the prediction model.This should provide potential guidance for air cleaner design.
What problem does this paper attempt to address?