Abstract:Combined process of coagulation-Fenton oxidation-biochemical-O3oxidation was applied to treat emulsion wastewater from vehicle cleaning.According to the removal of pollutants from different treatment units with different experimental conditions, the optimal process parameters of each stage were determined.The results showed that, Finally, after optimized combined process treatment, the COD in wastewater reduced from 9.417 g/L to 31.7mg/L, the mass concentration of LAS reduced from 311.9 mg/L to 0.15 mg/L, and the mass concentration of NH3-N and PO43--P was 7.7 and 0.25 mg/L respectively.The chroma of wastewater was removed completely, and the effluent indexes could meet the first level discharge standard of GB 8978-1996.