Air Quality Effect of the Waste Incineration Power Plant in Nanshan District of Shenzhen City

Fei CHEN,Yang ZHOU,Jie HU,Xinsheng ZHU,Min XIE,Yan OUYANG,Fahe CHAI
DOI: https://doi.org/10.19758/j.cnki.issn1673-288x.2016.03.046
2016-01-01
Abstract:Based on the WRF output data, we used the CALPUFF modeling system to simulate the Air quality effect of the Waste incineration power plant in Nanshan District of Shenzhen City?The simulation result showed that the maximum hourly concentration of SO2、 NO2 and HCl was 19?0μg/m3 , 42?0μg/m3 and 5?27μg/m3 , respectively. All of the maximum hourly concentrations in the area reach the standard?The maximum daily average concentration of SO2、 NO2、 HCl and PM10 was 2?5μg/m3 , 5?2μg/m3 , 0?68μg/m3 and 0?83μg/m3 , respectively. The maximum annual average concentration of SO2、NO2、 PM10 and Hg was 0?11μg/m3 , 0?28μg/m3 , 0?04μg/m3 and 0?081ng/m3 , respectively. The effect of the surrounding atmospheric environment is little and can meet the requirements of environmental quality standards.
What problem does this paper attempt to address?