Research on the treatment of cobaIt hydrometaIIurgicaI wastewater by Ti/RuO2-IrO2 eIectrode eIectrocataIytic oxidation

Lirui Liao,Dongfang Liu,Wenli Huang,Zhendong Wang,Wenjiao Li
DOI: https://doi.org/10.11894/iwt.2018-0544
2019-01-01
Abstract:In order to solve the problem that the comparatively high organic matter content in cobalt hydrometallurgi-cal wastewater affects the recovery quality of Na2SO4,the research on electrocatalytic oxidation treatment of this kind of wastewater has been implemented. Using the removing rate of COD as an assessment index,the relationship bet-ween COD removing rate and reaction time,current density,initial pH,plate spacing are discussed,based on a series of single-factor experiments. Through response surface optimization experiments,the optimal conditions within the target range have been obtained. Under these conditions,the COD removing rate can reach 71.72%. Combined with reaction energy consumption,the optimization experiments have been implemented again. Under the optimized condi-tions,the COD removing rate is 69.75%,and the average reaction energy consumption 0.173 5 kW·h/g.