Abstract:The experimental research on the advanced treatment of landfill leachate secondary effluent by UV/O 3 ad-vanced oxidation combined process has been conducted. The influences of the factors,such as reaction time,pH and ozone intake air flow rate on the treatment effects have been investigated. The results show that the optimum technical conditions are as follows:pH is 9,ozone intake air flow rate 80 L/h,power of UV light 10 W and reaction time 120 min. Under the best technical conditions,the removing rates of COD,ammonia nitrogen,and chroma of landfill leachate secondary effluent by UV/O3 combined advanced oxidation process are 80.61%,64.47%,91.70%, respectively. Compared with that of single ozone treatment process,the removing rates have been increased by 19.31%,17.77%,6.10%,respectively.