Study on the performance of roadway fireproofing in the stereo garage

Li LI,Zhi LI,Changcheng LIU,Song LU
DOI: https://doi.org/10.3969/j.issn.1004-5309.2015.02.07
2015-01-01
Fire Safety Science
Abstract:Effects of fire separation and top smoke exhaust of the roadway in the mechanical and stereo garage are studied by Fire Dynamics Simulator (FDS) .The fire probability of this stereo garage is confirmed as 0 .00786 case/year .According to previous researches ,the heat release rate of single car is studied .For a 6 m wide roadway ,simulation results show that a fire in one side would not ignite cars in the other side with a radiation ranging from 0 .6 kW/m2 to 2 .0 kW/m2 .When setting shutters on the roof ,the visibility of the burning storage unit and its opposite unit at 500 s at the 10 m height decreases less than 10 m ,while the visibility of the whole garage would drop to 10 m below ,even under 2 m partly if not setting shutters on the roof .All above demonstrate that natural smoke exhausting on the top could control hot smoke effectively .
What problem does this paper attempt to address?