Numerical Simulation of Fire Smoke Propagation in a Non-straight Road Tunnel

Li-xin GAO,Xiao-ying LU,Shao-zeng SUN
2011-01-01
Abstract:Numerical simulations for fires of 30MW for different fire locations and ventilation scenarios are conducted based on full scale experiments in a non-straight road tunnel due to the fact that most fire experiments and simulations are carried out in straight tunnels before.Results show that the performance of different ventilation scenarios differed from each other largely;longitudinal velocity had a strong influence on the propagation of smoke;smoke backlayering became weaker and smoke front moved faster with the increase of longitudinal velocity;the movement of smoke in longitudinal direction is hindered by the small longitudinal velocity of about zero in the vicinity of a fire located in the curved section of the tunnel;the existing emergency ventilation system cannot prevent backlayering effectively,other ventilation measures have to be provided.
What problem does this paper attempt to address?