Effects of Tip-Clearance on Unsteady Exciting Force and Down-Stream Stator Vibration

An-jian WEN,Xiao-tian LUO,Wei MA,Jin-fang TENG
DOI: https://doi.org/10.13675/j.cnki.tjjs.2018.01.007
2018-01-01
Abstract:Tip clearance of compressor blade will produce leakage flow,which can have a certain impact on unsteady flow and downstream stator.In order to study the unsteady flow excitation force and the vibration re?sponse of stator blades under different blade tip-clearances,the unsteady flow of single-stage compressor under different blade clearance is calculated. The flow characteristics of the unsteady results are then analyzed. After that,the unsteady exciting force of the stator surface is analyzed by fast Fourier transform,and the load is ap?plied to the stator by frequency to solve the vibration response.Unsteady flow results indicate that as the tip clear?ance increase,the efficiency and the pressure ratio are linearly decreasing.In addition,the time average pres?sure on the surface also decreases.The frequency domain of the excitation force shows that the main frequency of the excitation force is close to the frequency of the blade passing frequency,and the first-order exciting force ef?fect is the largest.And the results of vibration response show that the amplitude of the vibration decreases with the increase of the blade tip-clearance,but at 20%~40% leaf height,there is a nonlinear phenomenon,the dis?placement has a slight decline.The first three order response results are close to the modal shapes of 3rd,8th and 17th order,and the frequency difference is about 10%.
What problem does this paper attempt to address?