Investigation on a Novel Radial Air Intake System

Dong SHAO,Zhi-gang SUN,Shi-xun WU,Yong-sheng TIAN,Chun-qing TAN
DOI: https://doi.org/10.13675/j.cnki.tjjs.2017.12.012
2017-01-01
Abstract:Considering the geometry restraints and wide mass flow range requirements,the discharge quali?ty of the radial air intake system for a dual shaft compressor test rig is difficult to be guaranteed. Traditional solu?tion like multiple guided vanes could not meet the requirements over wide mass flow range. A novel design was ex?plored to improve flow uniformity,which made full use of the uniforming and guiding characteristics of honey?combs. The numerical results show satisfactory discharge distributions at the exit of the system over wide mass flow range,the maximum flow angle is less than 1°,the nonuniformity of velocity is less than 4.07%,and the to?tal pressure recovery coefficient is higher than 97.3%. Furthermore,some experiment results show good flow qual?ities as predicted.
What problem does this paper attempt to address?