Concentration Measurement of Carbon Monoxide in Combustion Chamber of an ADN-Based Propellant Thruster

Wei ZHANG,Yan SHEN,Xi-long YU,Zhao-pu YAO,Meng WANG,Hui ZENG,Fei LI,Shao-hua ZHANG
DOI: https://doi.org/10.13675/j.cnki.tjjs.2015.05.002
2015-01-01
Abstract:A tunable diode laser absorption spectroscopy(TDLAS)system was set up to investigate the combustion process of ADN-based propellant thruster. In the experiment,the mole fraction of CO was measured by using direct absorption scheme. The temporal variation of mole fraction of CO was experimentally obtained with respect to various injection pressure such as 1.1MPa,0.9MPa,0.7MPa,and 0.5MPa. Experimental results indicate that when the injection pressure was reduced from 1.1MPa to 0.5MPa,the average mole fraction of CO increased from 2% to 4.7%.It is shown that the injection pressure could have a crucial influence on the chemical reaction procedure of ADN-based propellant and the mole fraction of CO will arise as injection pressure decreases. Therefore,energy release of ADN-based propellant is insufficient in the case of low injection pressure.