Use of Oxidation-Reduction Potential to Monitor Iron Release from Corroded Iron Pipes in Drinking Water Distribution System

Wei JIANG,Jing-qing LIU,Ping YE,Hang-jia LI
DOI: https://doi.org/10.3785/j.issn.1008-973x.2015.04.023
2015-01-01
Abstract:Pipe scale samples were obtained from two pilot‐scale drinking water distribution systems in an eastern city ,and analyzed with SEM ,EDS and XRD .Results indicate that physicochemical characteristics of two pipe scale are similar ;Pipe scale surface is covered with shell‐like layer ;Major elements are Fe ,O and C , and main substances are Fe3 O4 and FeOOH . By pilot study , correlation between oxidation‐reduction potential (ORP) and iron release in stagnant water was investigated in different seasons ,and was compared with iron release correlations of dissolved oxygen (DO ) and turbidity . Results show that although pipe scales characteristics are similar ,changes in water quality during transmission can cause significant differences in iron release .Iron release from the same pipe was various in different seasons . ORP can be an indicator in predicting iron release .When ORP> 200 mV ,iron release is governed and there is no dissolved iron release . When ORP < 200 mV ,iron release severely and dissolved iron can release .ORP correlates iron release better than DO .
What problem does this paper attempt to address?