Detection efficiency evaluation for a large area neutron sensitive microchannel plate detector

Yi-ming Wang,Yang Tian,Yi-gang Yang,Ren Liu,Jing-sheng Pan,Xue-wu Wang,Zhi Zhang
DOI: https://doi.org/10.1088/1674-1137/40/9/096004
IF: 2.944
2016-09-01
Chinese Physics C
Abstract:In this paper, the detection efficiency of a large area neutron sensitive microchannel plate detector has been evaluated. A 6LiF/ZnS scintillator detector 65 mm in diameter and 0.32 mm in thickness, with product code, EJ426HD2, produced by Eljen Technology, was employed as the benchmark detector. The TOF spectra of these two detectors were simultaneously measured and the energy spectra were then deduced to calculate the detection efficiency curve of the nMCP detector. Tests show the detection efficiency@25.3 meV thermal neutrons is 34% for this nMCP detector.
physics, particles & fields, nuclear
What problem does this paper attempt to address?