Microwave Hydrothermal Sulfidation Process for Zinc-Containing Plating Sludge

Hao Tan,Junxun Jin,Yuchao Shao,Dan Zhou,Ying Zhou,Zixiao Wu,Minjin Wu,Dongsheng Shen,Yuyang Long
DOI: https://doi.org/10.1080/01496395.2020.1866606
IF: 2.799
2020-01-01
Separation Science and Technology
Abstract:The present study describes the conversion of zinc into a sulfide-containing plating sludge via a microwave hydrothermal sulfidation (MHS) process for use in heavy metal remediation by flotation. The research herein focused on circumventing the operational issues of traditional hydrothermal sulfidation (THS) at high temperature and high pressure. The following optimized process conditions of temperature 153 degrees C, reaction time 63 min, liquid-to-solid ratio 16:1 and S2- concentration 49% were obtained using a single-factor test and the Box-Behnken design test, to yield a maximum sulfidation ratio of 92.90%. Moreover, the economic analysis shows the superiority of the MHS process.
What problem does this paper attempt to address?