A Piezoelectric AlN MEMS Hydrophone with High Sensitivity and Low Noise Density

Dengfei Yang,Lei Yang,Xuying Chen,Mengjiao Qu,Ke Zhu,Hong Ding,Dongsheng Li,Yun Bai,Jian Ling,Jinghui Xu,Jin Xie
DOI: https://doi.org/10.1016/j.sna.2020.112493
IF: 4.291
2020-01-01
Sensors and Actuators A Physical
Abstract:This paper presents a micromachined hydrophone with high sensitivity and low noise density. The hydrophone is composed of a 10by10 piezoelectric aluminum nitride (AlN) membrane array, a low noise amplification circuit, and packaged by an acoustic transparent material. Equivalent noise model is used to analyze the equivalent input noise of receiving system, which can be effective to reducing the noise floor by choosing appropriate components. Moreover, a new pouring method is applied to improve the acoustic performance of the matching layer. The experiment results show that the packaged MEMS hydrophone achieves an acoustic sensitivity of -178 dB (Ref. 1 V/mu Pa), a bandwidth from 100 Hz to 1600 Hz, and an equivalent noise density of 52.6 dB@100 Hz (Ref. mu Pa/root Hz). The enhanced hydrophone is beneficial to achieve weak signals detecting in pipeline leak detection, marine noise monitoring and many other low frequency engineering applications. (C) 2020 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?