Effect of vacuum degree of milking machine on milk somatic cell counts (SCC) and teat end wall thickness

Li Xiaoming,Gao Zhenjiang,Jin Hongwei,Xiao Hongwei,Wang Jun,Zhang Weiwei
DOI: https://doi.org/10.11975/j.issn.1002-6819.2017.09.041
2017-01-01
Abstract:The same type of milking machine has the different system vacuum degree, and its set value is mainly from experience and lacks a specific scientific basis. However, during milk processing, farms keep the factory setting value of system vacuum degree for all dairy cows, which causes obvious health problems of dairy cows. Therefore, it is imperative to provide the scientific setting basis of system vacuum degree by quantifying the effect of milking machine system vacuum degree on milking characteristics and cows' health. The dry test and wet test were carried out at China Agricultural Machinery Testing Centre. Simulation milking device was applied to simulate peak milking process with the milk flow of 4.0 kg/min for the high yield dairy cow and 2.5 kg/min for the low yield dairy cow. The pulsation rate and pulsation ratio were set to 60 cycles/min and 60%, respectively, which remained unchanged throughout the experiment. System vacuum degree was set at 44, 46 and 48 kPa, respectively, by means of the vacuum regulator. VaDia vacuum tester was used for data acquisition when milking machine ran under no-load or simulated the milking process at each system vacuum degree. The milking time test was carried out at a dairy cattle field in the north of Jinan, Shandong Province. The setting program of pulsation rate and pulsation ratio was the same in dry test and wet test. Twelve high yielding Chinese Holstein cows were randomly selected. In continuous 3 months (from July to September), milking machine system vacuum degree was set at 44, 46 and 48 kPa respectively. Milking was performed at 5:00 and 17:00 every day, and milk yield, somatic cell count (SCC), milking time (only in morning milking) and teat end wall thickness before and after milking (only in morning milking) were measured. All parameters measured were compared with ANOVA (analysis of variance) using SPSS. The comparisons of multiple means were made using the Duncan's multiple range test, in order to classify the effect of the different treatments. The logarithm of SCC was used to normalize the distribution of SCC. The results showed that during peak milk flow period and over milking period, system vacuum degree was increased from 44 to 48 kPa, and the increasing rate of liner vacuum degree was 4.9% (P<0.001) and 10.8% (P<0.001), respectively. Meanwhile, the increasing rate of milking cup mouth vacuum degree was 373.8% (P<0.001) and 53.7%(P<0.001), respectively. There were no significant differences for milk yield, average milk flow rate and milking time except the logarithm of SCC (P<0.05) between 44 and 48 kPa system vacuum degree. Percentage change of the teat end wall thickness was lower at the lower system vacuum level (44 kPa) after milking, and increased (P<0.05) as the system vacuum level was raised to 48 kPa. The findings of this study indicated that with a lower vacuum level of 44 kPa, the cows were milked better than those with 46 or 48 kPa. The findings in current work provide a technical support for the optimization settings of working state parameters of milking machine in mechanization milking parlors in China.
What problem does this paper attempt to address?