Detection of Glucose and Glutathione Based on Nanozymatic and Photoelectrochemical Activities of Au@SH-MIL-101(Fe)
Cui-Ru Chen,Cong-Yi Hu,Cheng-Zhi Huang,Yuan-Fang Li
DOI: https://doi.org/10.19756/j.issn.0253-3820.231444
IF: 1.193
2024-01-01
Chinese Journal of Analytical Chemistry
Abstract:With the rapid development of nanotechnology, the preparation of multifunctional nanomaterials has become a hot research direction in recent years. In particular, gold nanoparticles (AuNPs) are multifunctional, but they are easy to agglomerate into larger particles, affecting their catalytic performance. Using metal -organic framework (MOF) as carriers to suppress the aggregation of AuNPs to obtain multifunctional nanocomposites is a very promising strategy. In this work, a facile and rapid method for loading AuNPs onto surface of SH-MIL-101(Fe) to prepare Au@SH-MIL-101(Fe) nanocomposites was developed. The obtained Au@SH-MIL-101(Fe) exhibited excellent peroxidase (POD) -like activity and the photoelectrochemical (PEC) activity. The structure and chemical composition of Au@SH-MIL-101(Fe) were characterized by powder X-ray diffraction (PXRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FT-IR), respectively. Based on the POD -like activity, Au@SH-MIL-1O1(Fe) could catalyze hydrogen peroxide (H202) into produce hydroxyl radicals (center dot OH) to oxidize 3,3',5,5'-tetramethylbenzidine (TMB) at neutral pH to obtain blue oxidation product oxTMB. Therefore, a rapid and sensitive colorimetric method for detection of glucose was established based on the glucose oxidase catalyzing glucose to produce H202. The linear range for detection of glucose was 1.0-200.0 mu mo1IL, and the detection limit (S/N=3) was 0.64 mu mol/L. The colorimetric method was used to detect glucose in serum, and the recoveries were 91.7%-106.6%. In addition, Au@SH-MIL-1O1(Fe) could form an Au -S bond with the sulfhydryl group in GSH to produce a steric hindrance, thereby reducing the photocurrent of Au@SH-MIL-1O1(Fe). A novel PEC sensor for detection of GSH was constructed by using the superb PEC activity of Au@SH-MIL-1O1(Fe). The linear detection range of GSH by PEC strategy was 1.0-50.0 nmol/L, and the detection limit (SIN=3) was 0.20 nmol/L. The PEC method was used to detect GSH in serum, and the recoveries was 95.0%-104.5%. The prepared Au@SH-MIL-1O1(Fe) nanocomposites might provide new insights into the synthesis of innovative multifunctional nanomaterials and promising candidates for clinical applications.