Role of 18 F-FDG PET/CT imaging in cardiac and pericardial masses

Hongyan Yin,Wujian Mao,Hui Tan,Na Zhu,Quan Wan,Jing Shi,Lin Qiu,Yan Xiu,Rongkui Luo,Haojun Yu,Hongcheng Shi
DOI: https://doi.org/10.1007/s12350-020-02510-9
2021-01-01
Journal of Nuclear Cardiology
Abstract:Background Considering the few reported cardiac masses, PET/CT in the imaging workup of cardiac masses is not well established. This retrospective study analyzed the role of 18 F-FDG PET/CT imaging in cardiac/pericardial masses. Methods and results Fifty-nine patients with newly diagnosed cardiac/pericardial masses who underwent PET/CT and transthoracic echocardiography (TTE) were recruited. Echocardiographic and PET/CT characteristics were evaluated for predictive value in differentiating malignant and non-malignant lesions using histologic confirmation as the gold standard. The McNemar test was used to test the differences in sensitivity between PET/CT and TTE. 18 F-FDG PET/CT had higher sensitivity in determining the malignancy of cardiac/pericardial masses compared to TTE (sensitivity, 96.6% vs 72.4%, P = .039). However, when pericardial masses were excluded from the analysis, the difference in sensitivity between the two was not statistically significant (sensitivity, 95.6% vs 78.3%, P = .219). 18 F-FDG PET/CT identified two malignant pericardial masses missed on TTE, changed the diagnostic orientation of TTE in 15 patients, and found seven patients with extracardiac lesions in 29 malignant patients. Conclusions PET/CT was an effective additional image modality in patients with suspected malignant cardiac mass for further confirmation and to screen for potential metastasis.
What problem does this paper attempt to address?