An AC-Coupled Instrumentation Amplifier Achieving 110-Db CMRR at 50 Hz with Chopped Pseudoresistors and Successive-Approximation-Based Capacitor Trimming.

Sanfeng Zhang,Xiong Zhou,Chen Gao,Qiang Li
DOI: https://doi.org/10.1109/jssc.2020.3010816
IF: 5.4
2020-01-01
IEEE Journal of Solid-State Circuits
Abstract:High common-mode rejection ratio (CMRR) with concurrent electrode offset rejection is essential for physiological signal acquisitions. This article presents a CMRR enhancement technique for ac-coupled instrumentation amplifiers (ACIAs), where the mismatch of passive components limits the CMRR performance primarily. A modified chopping structure is proposed to mitigate the mismatch effect of the pseudoresistors, and a successive-approximation based capacitor trimming loop is exploited. Fabricated in a 0.18-μm CMOS technology, the ACIA draws 2.3 μA from a 1.2-V supply and exhibits 3.2-μV rms input-referred noise over 0.5-400 Hz. The measured prototypes achieve >110-dB CMRR at 50/60 Hz without any off-chip tuning.
What problem does this paper attempt to address?