Microscopic Characteristic and Transmittance Measurement of Infrared Smoke Combustion Product

Zhu Xijuan,Ma Jing,Zhou Yue,Zhu Chenguang,Lin Juan
DOI: https://doi.org/10.1016/j.procs.2020.06.138
2020-01-01
Procedia Computer Science
Abstract:The concentration, microscopic characterization and transmittance of a P(A)SiO2 smoke product with different SiO2 ratios were measured by using particle collector, scanning electron microscopy and infrared spectrometer. The micro-Characterization of the product and the effect of the product on the transmittance were analyzed. The results show that the proportion of SiO2 has no linear effect on smoke concentration, and there is an optimal proportion; the size of particulate matter of smoke products is about 10-20 μm, and the structure is irregular; The transmittance of smoke is affected by concentration in the early stage of smoke release. The higher the concentration, the lower the transmittance. The later stage of smoke release is mainly affected by particulate deposition. The higher the settling speed, the faster the transmittance increases.
What problem does this paper attempt to address?